3V0-21.21 Practice Exams and Training Solutions for Certifications [Q22-Q47]

Share

3V0-21.21 Practice Exams and Training Solutions for Certifications

Dumps Free Test Engine Player Verified Answers


VMware 3V0-21.21 (Advanced Design VMware vSphere 7.x) Certification Exam is a well-recognized certification exam that tests the candidates' advanced knowledge and skills in designing and deploying VMware vSphere 7.x solutions. Advanced Design VMware vSphere 7.x certification exam is designed for experienced IT professionals, solution architects, and consultants who have a deep understanding of vSphere 7.x and its advanced features and functionalities.

 

NEW QUESTION # 22
An architect is designing a solution based on the following information:
Each ESXi host has a single physical NIC with two 10 Gbps ports.
There is a performance-based service-level agreement (SLA) that guarantees 15 Gbps bandwidth for production virtual machines at all times.
There is no budget to purchase additional hardware.
The hardware replacement SLA is based on a delivery agreement of two business days.
Which recommendation for the configuration of vSphere High Availability (HA) should the architect include in the design?

  • A. Configure vSphere HA
    Configure % based admission control Configure two isolation addresses
    Consider an OEM with NIC failure conditions in their Proactive HA plugin
  • B. Configure vSphere HA
    Configure two existing data stores for heartbeat
    Consider an OEM with NIC failure conditions in their Proactive HA plugin
  • C. Configure vSphere HA
    Set das.IgnoreRedundantNetWarning to true
    Consider an OEM with NIC failure conditions in their Proactive HA plugin
  • D. Configure Proactive HA Automation Level: Automated
    Remediation: Maintenance mode for all failures
    Consider an OEM with NIC failure conditions in their Proactive HA plugin

Answer: A


NEW QUESTION # 23
An architect is considering placement of virtual machines within an existing VMware software-defined data center (SDDC).
During the discovery phase, the following information is documented:

Which two recommendations should the architect make for placement of the virtual machines to meet resource profile requirements? (Choose two.)

  • A. All virtual machines matching Virtual Machine Resource Profile 2 should be placed on Cluster One.
  • B. All virtual machines matching Virtual Machine Resource Profile 2 should be placed on Cluster Three.
  • C. All virtual machines matching Virtual Machine Resource Profile 1 should be placed on Cluster Two.
  • D. All virtual machines matching Virtual Machine Resource Profile 1 should be placed on Cluster One.
  • E. All virtual machines matching Virtual Machine Resource Profile 2 should be placed on Cluster Two.

Answer: B,C

Explanation:
https://docs.vmware.com/en/VMware-vSphere/7.0/com.vmware.vsphere.resmgmt.doc/GUID-FEAC3A43-C57E-49A2-8303-B06DBC9054C5.html


NEW QUESTION # 24
Which two of the listed requirements would be classified as performance non-functional requirements? (Choose two.)

  • A. The vSphere platform must be able to provide N+1 redundancy
  • B. The vSphere platform must be able to provide a recovery time objective of 30 minutes
  • C. The vSphere platform must be able to provide a minimum throughput of 400 MB/s
  • D. The vSphere platform must be able to provide a maximum read latency of 15 ms
  • E. The vSphere platform must be able to provide a service-level agreement (SLA) of 99,9%

Answer: B,D


NEW QUESTION # 25
During a requirements gathering workshop to design a physical to virtual migration, the customer provides the following information:
* There is no physical firewall in the data center with no anticipated plans for a future network refresh.
* Leveraging the virtual infrastructure to mitigate the lack of network security must be addressed in the design.
* All physical servers to be migrated exist on the same VLAN.
Which recommendation should the architect make to address the customer requirement with regard to virtual networking?

  • A. Disable traffic filtering and marking
    Use tag actions
  • B. Enable traffic filtering and marking
    Use allow or drop actions
  • C. Create port groups with different names and same VLAN IDs
    Enable traffic shaping for ingress and egress traffic
  • D. Split the virtual machines into several VLANs
    Use tag actions

Answer: D


NEW QUESTION # 26
An architect is preparing a design for a company planning digital transformation. During the requirements gathering workshop, the following requirements (REQ) and constraints (CON) are identified:
REQ01 The platform must host different types of workloads including applications that must be compliant with internal security standard.
REQ02 The infrastructure must initially run 100 virtual machines.
REQ03 Ten of the virtual machines must be compliant with internal security standard.
REQ04 The internal security standard specifies logical network separation for in-scope applications.
CON01 The customer has already purchased the licenses as part of another project.
CON02 The customer has five physical servers that must be reused.
Additionally, based on resource requirements, four physical servers will be enough to run all workloads. Which recommendation should the architect make to meet requirements while minimizing project costs?

  • A. Use Network I/O Control to ensure the internal security zone has higher share value
  • B. Use a single cluster and ensure that different security zones are separated at least with dedicated VLANs and firewall
  • C. Use a single cluster and configure DRS anti-affinity rules to ensure internal security compliant virtual machines cannot migrate between ESXi hosts.
  • D. Purchase additional servers and plan separate, isolated clusters for workloads that must be compliant with internal security

Answer: B


NEW QUESTION # 27
A VMware Service Provider is tasked with delivering a solution for continuous availability for a subset of Tier 1 virtual machines (VMs) and vApps running in their vSAN environment. The VMs make up a mission-critical application and there can be no data loss in the event of an outage at their primary data center. In the event of a regional outage, they have established a 10-minute recovery point objective (RPO). Failover/failback to the third site must be automated.
They have the following in place:
Two local data centers (primary and secondary) connected with 100 Gb dedicated fiber
2ms round-trip time (RTT) latency between the sites
A third data center located on another power grid
70ms latency between the primary and secondary data centers
Matching storage arrays at all locations
Which two solutions could be used to meet the requirements? (Choose two.)

  • A. vSphere Data Protection
  • B. vSAN Metro Cluster
  • C. vStorage APIs for Array Integration (VAAI)
  • D. Snapshots
  • E. Site Recovery Manager

Answer: B,E

Explanation:
https://core.vmware.com/resource/vsan-stretched-cluster-guide#section1
https://www.delltechnologies.com/asset/en-us/products/converged-infrastructure/technical-support/vxrail-stretched-cluster-planning-guide-for-7-0.pdf
- a latency of less than or equal to 100 milliseconds is preferred.
Witness to Site -- less than 100msec; 200msec is acceptable https://www.delltechnologies.com/asset/en-us/products/converged-infrastructure/technical-support/vxrail-stretched-cluster-planning-guide-for-7-0.pdf - a latency of less than or equal to 100 milliseconds is preferred.


NEW QUESTION # 28
An architect is considering placement of virtual machines within an existing VMware software-defined data center (SDDC).
During the discovery phase, the following information is documented:

Which two recommendations should the architect make for placement of the virtual machines to meet resource profile requirements? (Choose two.)

  • A. All virtual machines matching Virtual Machine Resource Profile 2 should be placed on Cluster One.
  • B. All virtual machines matching Virtual Machine Resource Profile 2 should be placed on Cluster Three.
  • C. All virtual machines matching Virtual Machine Resource Profile 1 should be placed on Cluster One.
  • D. All virtual machines matching Virtual Machine Resource Profile 1 should be placed on Cluster Two.
  • E. All virtual machines matching Virtual Machine Resource Profile 2 should be placed on Cluster Two.

Answer: C,D


NEW QUESTION # 29
A new real-time financial service application is being developed by the engineering team at a financial firm and will be released as a public Software-as-a-Service (SaaS) offering. The solutions architect has designed and deployed a new vSphere environment and the supporting network infrastructure for hosting all public services. ESXi hosts are configured to use Precision Time Proalhazi@1tocol (PTP) and a local stratum-1 network time server.
Application provisioning and scaling will be managed by VMware vRealize Automation and can be run on Microsoft Windows or multiple distributions of Linux.
Which three recommendations should the architect include in the design to ensure that the service maintain timekeeping within an accuracy of one second? (Choose three.)

  • A. Use Microsoft Windows Server as the guest operating system.
  • B. Add a virtual watchdog timer (VWDT) device to each virtual machine running the application.
  • C. Add a precision clock virtual device to each virtual machine running the application.
  • D. Configure the chrony time-sync agent on each virtual machine guest operating system.
  • E. Set the virtual hardware device to use Host System Time (NTP) for each virtual machine running the application.
  • F. Use a Linux distribution as the guest operating system.

Answer: C,D,F

Explanation:
https://blogs.vmware.com/apps/2021/04/lets-be-precise-enabling-and-configuring-precision-time-protocol-in-vsphere.html
https://core.vmware.com/blog/introducing-ptpvmw-new-linux-driver-achieve-high-time-synchronization-accuracy
https://blogs.vmware.com/apps/2020/09/ensuring-accurate-time-keeping-in-virtualized-active-directory-infrastructure.html


NEW QUESTION # 30
An architect is designing a VMware solution for a customer based on the following information:
The solution must use investments in existing storage array that supports both block and file storage.
The solution must support the ability to migrate workloads between hosts within a cluster.
The solution must support resource management priorities.
The solution must support the ability to connect virtual machines directly to LUNs.
The solution should use existing IPv4 based network infrastructure.
There is no budget for additional physical hardware.
Which two design decisions could the architect make to meet these requirements? (Choose two.)

  • A. The ESXi hosts will leverage iSCSI
  • B. The ESXi hosts will leverage Fibre Channel over Ethernet (FCoE)
  • C. The ESXi hosts will leverage NFS 3
  • D. The ESXi hosts will leverage Fibre Channel (FC)
  • E. The ESXi hosts will leverage NFS 4.1

Answer: A,E


NEW QUESTION # 31
An architect is creating a network design for a new vSphere environment.
Based on customer requirements, the environment must support the following types of traffic:
Management
vMotion
vSAN
Fault Tolerance
Virtual machine traffic, which cannot be impacted by other types of traffic Which design recommendation can the architect make for a resilient infrastructure with vSphere network service tiering?

  • A. Use Network I/O Control and ensure appropriate share value is defined for different types of traffic giving priority to the virtual machines traffic
  • B. Use a NIC teaming policy based on the physical NIC load
  • C. Use different logical networks to ensure traffic is isolated with separate VLANs
  • D. Use two dedicated virtual switches with a single adapter each, dedicating one virtual switch for Management, vMotion, vSAN and Fault Tolerance traffic, and the second one for virtual machine traffic

Answer: A

Explanation:
https://docs.vmware.com/en/VMware-vSphere/7.0/vsan-network-design-guide/GUID-6B00B437-53A3-4ACD-8CD7-AC9D0CE5BA8E.html


NEW QUESTION # 32
As part of a new hybrid cloud initiative for a large financial company, the customer technical team is presenting an overview of the current state of the infrastructure and their vision for a new solution.
The project team captures notes during the presentation and adds them to the discovery documentation. Which of the listed statements is a design constraint?

  • A. The applications are created in-house with in-guest recovery protection
  • B. The maximum tolerable data loss is 10 minutes
  • C. The two data center locations have a network latency of 8 ms round-trip time (RTT)
  • D. The existing storage is out of maintenance

Answer: C

Explanation:
Networking Requirements for vSAN
Maximum of 1 ms RTT for standard (non-stretched) vSAN clusters between all hosts in the cluster Maximum of 5 ms RTT between the two main sites for stretched clusters Maximum of 200 ms RTT from a main site to the vSAN witness host
https://docs.vmware.com/en/VMware-vSphere/7.0/com.vmware.vsphere.vsan-planning.doc/GUID-AFF133BC-F4B6-4753-815F-20D3D752D898.html


NEW QUESTION # 33
Refer to the exhibit.
During a requirements gathering workshop, the architect shares the following diagram:

What should the architect recommend for guaranteed throughput for each service?

  • A. Create a link aggregation group (LAG) for vDS_01
    Use the Route Based on Physical NIC Load for vMotion Use the Route Based on Physical NIC Load for replication
  • B. Use the Route Based on IP Hash for ESXi management and VM network Use failover with pNIC1 as Active for backup network Create a link aggregation group (LAG) for vDS_02
  • C. Use the Route Based on IP Hash for ESXi management and VM network Use the Route Based on IP Hash for backup network Use the Route Based on the Originating Virtual Port for vMotion Use failover with pNIC3 as Active for replication
  • D. Use explicit failover order with pNIC0 as Active for ESXi Management and VM Network Use explicit failover order with pNIC1 as Active for backup network Use explicit failover order with pNIC2 as Active for vMotion Use explicit failover order with pNIC3 as Active for replication

Answer: D


NEW QUESTION # 34
An architect is designing a new vSphere platform for a customer to meet the following requirements:
The platform must be deployed into five physically separate sites.
The sites are spread across multiple regions.
Some sites require more than one vCenter Server.
The platform must provide an administrator with the ability to access virtual infrastructure components across all sites from a single management tool instance.
Which single sign-on (SSO) design recommendation will meet these requirements?

  • A. Use an SSO domain per vCenter Server instance
  • B. Use an SSO domain per region
  • C. Use an SSO domain per site
  • D. Use an SSO domain across all vCenter Server instances

Answer: A


NEW QUESTION # 35
An architect is finalizing the design for a new vCenter Server High Availability deployment.
What is one thing the architect must document in the design?

  • A. The load balancing algorithm used by the Management Distributed Virtual Switches (DVS)
  • B. The details of each of the vCenter Server licenses for active, passive and witness nodes
  • C. The vCenter Management Network IPv4 addresses for the witness node vCenter Server
  • D. The SSH configuration settings for the vCenter Server's active node

Answer: D

Explanation:
vCenter HA uses SSH keys for password-less authentication between the Active, Passive, and Witness nodes. The authentication is used for heartbeat exchange and file and data replication. To replace the SSH keys in the nodes of a vCenter HA cluster, you deactivate the cluster, generate new SSH keys on the Active node, transfer the keys to the passive node, and activate the cluster.
https://docs.vmware.com/en/VMware-vSphere/7.0/com.vmware.vsphere.avail.doc/GUID-B8E590BA-ACF4-48A1-8644-E492D2241031.html
https://docs.vmware.com/en/VMware-vSphere/7.0/com.vmware.vsphere.avail.doc/GUID-5F7DAFB2-60BD-4C50-A7E5-29A319CBB714.html


NEW QUESTION # 36
An architect will be taking over control of a former Linux server fleet and repurposing the hardware into a new vSphere cluster. The current environment is already connected to the network but the hosts do not have any local disks. Since the fleet hardware is uniform, the architect can use a single ESXi image. All hosts within the cluster have the same CPU and memory capacity.
Which ESXi deployment method should the architect use?

  • A. Stateless cached vSphere Auto Deploy
  • B. Manual install of each ESXi host with an image from USB
  • C. Stateless vSphere Auto Deploy
  • D. Stateful vSphere Auto Deploy

Answer: C


NEW QUESTION # 37
Refer to the exhibit.

During a requirements gathering workshop, the customer shares the following about their existing ESXi host virtual networking infrastructure:
The customer confirms that:
Each ESXi host has approximately 200 virtual machines.
They want to maximize the number of concurrent virtual machine migrations.
When placing a host in maintenance mode, it takes a long time to evacuate the virtual machines.
Which two recommendations should the architect make in order to help the customer overcome their challenge? (Choose two.)

  • A. Configure the network to use MTU for the VMotion VMKernel to 9,000 bytes
  • B. Configure the network to use MTU for the VMotion VMKernel to 1,600 bytes
  • C. Create an additional standard switch with pNIC3 to use for vMotion
  • D. Use 10 GbE NICs instead of 1 GbE
  • E. Use the 3 pNICs and bundle them in a link aggregation group (LAG) configuration

Answer: A,D

Explanation:
https://docs.vmware.com/en/VMware-vSphere/7.0/com.vmware.vsphere.vcenterhost.doc/GUID-7DAD15D4-7F41-4913-9F16-567289E22977.html
10Gb maximizes the amount of bandwidth, as well as increases the number of potential simultaneous vmotions.


NEW QUESTION # 38
Refer to the exhibit.
During a requirements gathering workshop, a customer shares the following diagram regarding their availability service-level agreements (SLAs):

The customer states that there is no application level availability for legacy applications.
Which recommendation could the architect make to meet the customer's high availability requirements for the legacy applications virtual machines?

  • A. Enable Fault Tolerance
  • B. Enable vSphere HA and add a VM Override with VM Restart Priority set to Lowest
  • C. Achieve application availability with snapshots
  • D. Enable vSphere HA and add a VM Override with VM Restart Priority set to Disabled

Answer: D

Explanation:
Explanation/Reference:


NEW QUESTION # 39
An architect is designing a new backup solution for a vSphere platform that has been recently upgraded to vSphere 7.
The architect wants the backup solution to perform the following:
Full virtual machine image backup and restore
Incremental virtual machine image backup and restore
File level backup and restore within both Windows and Linux virtual machines LAN-free backup Which functional requirement should the architect include in the design of the new backup solution?

  • A. The backup solution must leverage virtual machine snapshots.
  • B. The backup solution must leverage the VMware Consolidated Backup (VCB) framework.
  • C. The backup solution must leverage VMware vStorage APIs for Data Protection (VADP).
  • D. The backup solution must leverage VMware vSphere Storage APIs - Data Protection.

Answer: D


NEW QUESTION # 40
A VMware Service Provider is tasked with delivering a solution for continuous availability for a subset of Tier 1 virtual machines (VMs) and vApps running in their vSAN environment. The VMs make up a mission-critical application and there can be no data loss in the event of an outage at their primary data center. In the event of a regional outage, they have established a 10-minute recovery point objective (RPO). Failover/failback to the third site must be automated.
They have the following in place:
Two local data centers (primary and secondary) connected with 100 Gb dedicated fiber
2ms round-trip time (RTT) latency between the sites
A third data center located on another power grid
70ms latency between the primary and secondary data centers
Matching storage arrays at all locations
Which two solutions could be used to meet the requirements? (Choose two.)

  • A. vSphere Data Protection
  • B. vSAN Metro Cluster
  • C. vStorage APIs for Array Integration (VAAI)
  • D. Snapshots
  • E. Site Recovery Manager

Answer: B,E

Explanation:
https://core.vmware.com/resource/vsan-stretched-cluster-guide#section1


NEW QUESTION # 41
An architect is tasked with designing a greenfield VMware software-defined data center (SDDC) solution that will be used to deliver a private cloud service for a customer.
During the initial meeting with the service owner and business sponsor, the customer has provided the following information to help inform the design:
The solution must initially support the concurrent running of 300 production and 600 development virtual machines.
The production environment should be delivered across two geographically dispersed data centers. The development environment must be vSphere-based but does not have to be deployed on-premises.
The two data centers are connected to each other through multiple diversely routed, high bandwidth and low latency links.
The customer's server hardware standard document states that all virtual infrastructure hosts must be based on blade architecture only.
The service owner has said that is important to ensure that neither the availability target of 99.5% nor the resource capacity is affected when the operations team completes maintenance activities, such as the monthly software patching and ad-hoc hardware break/fix.
All virtual machine backups must be completed using the existing backup service. The recovery time objective (RTO) for the service is four hours.
The recovery point objective (RPO) of the service is 24 hours.
Given the information from the customer, which two would be classified as assumptions within the design? (Choose two.)

  • A. The backup service has sufficient capacity for the new requirements
  • B. The backup service will store data in a secure facility
  • C. The customer will update their hardware standard to support rack mount servers
  • D. All virtual machines will be deployed with the same resource profile for production and development
  • E. The clusters will have a minimum redundancy of N+1

Answer: B,C


NEW QUESTION # 42
Which two statements are true about gathering functional business and application requirements? (Choose two.)

  • A. It is a non-iterative process
  • B. It builds stakeholder consensus
  • C. It focuses on functional requirements with C-level stakeholders
  • D. It might require multiple rounds of stakeholder interviews
  • E. It leverages a single set of

Answer: B,D

Explanation:
You interview stakeholders and conduct workshops to gather requirements and build consensus. Gathering requirements is an iterative process, which might require multiple rounds of interviews. Asking the right questions is vital, and you must gather both functional and nonfunctional requirements. A good strategy for a successful project is to bring the correct people together and build consensus.


NEW QUESTION # 43
An architect is designing a new vSphere environment with the following resources:
600 vCPU
5,760 GB RAM
Average resource usage is:
60 vCPU
1,152 GB RAM
The design must meet the following requirements:
The environment has the ability to burst by 25%.
Each host can schedule 36 vCPUs and has 512 GB RAM.
Management overhead is 20%.
What is the minimum number of hosts required to meet the design requirements?

  • A. Three
  • B. Four
  • C. Two
  • D. Five

Answer: B


NEW QUESTION # 44
Refer to the exhibit.
During a requirements gathering workshop, a customer shares the following diagram regarding their availability service-level agreements (SLAs):

The customer states that there is no application level availability for legacy applications.
Which recommendation could the architect make to meet the customer's high availability requirements for the legacy applications virtual machines?

  • A. Enable Fault Tolerance
  • B. Achieve application availability with snapshots
  • C. Enable vSphere HA and add a VM Override with VM Restart Priority set to Disabled
  • D. Enable vSphere HA and add a VM Override with VM Restart Priority set to Lowest

Answer: D


NEW QUESTION # 45
An architect will be taking over control of a former Linux server fleet and repurposing the hardware into a new vSphere cluster. The current environment is already connected to the network but the hosts do not have any local disks. Since the fleet hardware is uniform, the architect can use a single ESXi image. All hosts within the cluster have the same CPU and memory capacity.
Which ESXi deployment method should the architect use?

  • A. Stateless vSphere Auto Deploy
  • B. Manual install of each ESXi host with an image from USB
  • C. Stateless cached vSphere Auto Deploy
  • D. Stateful vSphere Auto Deploy

Answer: C

Explanation:
Explanation/Reference: https://docs.vmware.com/en/VMware-vSphere/7.0/com.vmware.esxi.install.doc/GUID-0813B4BE-
485D-4129-902B-49AA42EBF54E.html


NEW QUESTION # 46
Refer to the exhibit.
During a requirements gathering workshop, the architect shares the following diagram:

What should the architect recommend for guaranteed throughput for each service?

  • A. Create a link aggregation group (LAG) for vDS_01
    Use the Route Based on Physical NIC Load for vMotion Use the Route Based on Physical NIC Load for replication
  • B. Use the Route Based on IP Hash for ESXi management and VM network Use failover with pNIC1 as Active for backup network Create a link aggregation group (LAG) for vDS_02
  • C. Use explicit failover order with pNIC0 as Active for ESXi Management and VM Network Use explicit failover order with pNIC1 as Active for backup network Use explicit failover order with pNIC2 as Active for vMotion Use explicit failover order with pNIC3 as Active for replication
  • D. Use the Route Based on IP Hash for ESXi management and VM network Use the Route Based on IP Hash for backup network Use the Route Based on the Originating Virtual Port for vMotion Use failover with pNIC3 as Active for replication

Answer: D


NEW QUESTION # 47
......

Q&As with Explanations Verified & Correct Answers: https://www.exam4docs.com/3V0-21.21-study-questions.html

3V0-21.21 Dumps with Free 365 Days Update Fast Exam Updates: https://drive.google.com/open?id=1GKiMmvaoBIJpgHknWG98syzSdk8JsFuW